TM 9-4110-256-14
4-35.
AC MOTOR B2 TESTING AND REPLACEMENT. - Continued
(7)
If adjusting-motor mount bracket (13) must be replaced, remove four bolts (14), lock washers (15), and
bracket. Discard lock washers.
(8)
If motor mount bracket (16) must be replaced, remove four bolts (17), lock washers (18), and bracket.
Discard lock washers.
c. Installation.
(1)
If motor mount bracket (16) was removed, install bracket, four new lock washers (18), and bolts (17).
(2)
If adjusting-motor mount bracket (13) was removed, install bracket, four new lock washers (15), and bolts
(14).
(3)
Install new tab housing (19) and tab (20) onto each AC motor (4) wire lead (para 4-20).
(4)
Install key (12) and pulley (10). Tighten set screw (11).
(5)
Install AC motor (4) and slip V belt (9) onto pulley (10).
(6)
Install four flat washers (8) and new self locking nuts (7).
(7)
(8)
Install wire leads (3), strain relief cable bushing (6), and conduit locknut (5).
(9)
Using tags and wiring diagram (fig. 1-4), connect wire leads (3).
(10)
Install terminal cover (2) and four bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Connect power and put unit back into service.
4-76