4-37.
CONDENSER FAN REPLACEMENT.
This task covers: a. Removal
c. Installation
INITIAL SETUP
General Safety Instructions:
Equipment Conditions:
WARNING
disconnected.
Right side condenser door open.
High voltage and exposed rotating
parts are used in the refrigeration unit.
Personal injury can result if power is
connected.
a. Removal.
(1)
Loosen two set screws (1).
(2)
Carefully pull condenser fan (2) off fan drive shaft (3), being careful not to loose key (4), and remove from
condenser shroud (5).
b. Installation.
(1)
Place condenser fan (2) into condenser shroud (5).
(2)
Aline and install condenser fan (2) and key (4) onto fan drive shaft (3).
(3)
Tighten two set screws (1).
4-79