TM 9-4110-256-14
5-3.
CIRCUIT BREAKER COVER REPAIR.- Continued
(2)
Soften and remove old adhesive and gasket (1) or (2) residue, using acetone or methyl-ethyl ketone (MEK)
and a stiff brush.
(3)
(4)
Be sure that the attaching surface of the circuit breaker cover (3) is clean and free of paint and old
adhesive material.
(5)
Coat the mating surfaces of the circuit breaker cover (3) and gasket (1) or (2) with adhesive. Let both
surfaces air dry until adhesive is tacky, but will not stick to fingers.
(6)
Starting with an end, carefully press gasket (1) or (2) onto the circuit breaker cover (3). Press firmly overall
to ensure complete contact.
NOTE
FOLLOW-ON MAINTENANCE:
5-6