TM 9-4110-256-14
5-31.
ACCUMULATOR REPLACEMENT .
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Equipment Conditions:
Materials/Parts:
Lock Washers (4)
Refrigeration system discharged (para 5-8) and purged
Self Locking Nut
Insulation Tape
General Safety Instructions:
Lubricating Oil
WARNING
this refrigeration system is caustic.
Wear gloves and a face protector or
safety glasses in any situation where
skin or eye contact is possible. If oil
does contact skin, wash with soap
and water.
a. Removal.
(1) Remove insulation (1) as necessary.
(2) De-braze two fittings (2) from accumulator (3) (para 5-10).
Figure 5-27. Accumulator.
5-57