TM 9-4110-256-14
5-38. COMPRESSOR B1 TESTING, REPAIR, AND REPLACEMENT . - Continued
(11) Install cover (2) and two screws (1).
(12) Install center post (para 4-15) between front bottom doors.
NOTE
FOLLOW-ON MAINTENANCE
Close side condenser doors.
Close front bottom doors.
This task covers:
a. Repair
INITIAL SETUP
Tools:
Equipment Condition:
Drill Motor
disconnected.
Drill Bit Set
General Safety Instruction.:
Rivet Gun
WARNING
Materials/Parts:
High voltage and rotating parts are used in
the refrigeration unit. Personal injury can
Lock Washer (2)
result if power is connected.
Self Locking Nuts (12)
Self Locking Nut
Self Locking Nuts (34)
Silicone RTV
Repair.
NOTE
Repair to condenser frame at this maintenance level is limited to replacement of any damaged
rivets or blind rivet nuts and replacement of evaporator housing and heat shield.
(1) Drill through rivet or blind rivet nut using drill bit slightly smaller than rivet diameter.
5-78