TM 9-4110-258-13
4.35 FLANGE BEARINGS REPLACEMENT. - Continued
b. Installation.
(1) Install flange bearing (7), four flat washers (6), bolts (5), and new self locking nuts (4).
(2) Install flange bearing (3), four new lock washers (2), and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Connect power and put unit back into service.
4.36 CONDENSER FAN REPLACEMENT.
This task covers:
a. Removal
c. Installation
Equipment Conditions:
General Safety Instructions:
WARNING
disconnected.
Right side door open.
High voltage and exposed rotating parts are
used in the refrigeration unit. Personal injury
can result if power is connected.
a. Removal.
(1) Loosen two set screws (1).
(2) Carefully pull condenser fan (2) off fan drive shaft (3), being careful not to loose key (4), and remove from
condenser shroud (5).
b. Installation.
(1) Place condenser fan (2) into condenser shroud (5).
(2) Align and install condenser fan (2) and key (4) onto fan drive shaft (3).
(3) Tighten two set screws (1).
4-78