TM 9-4110-258-13
5.19
PRESSURE REGULATOR VALVE (DISCHARGE) REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Materials/Parts
Lock Washer
Insulation Tape
Left side door open.
a. Removal.
(1) Remove insulation (1) as necessary.
(2) Remove bolt (2), lock washer (3), and clamp (4). Discard lock washer.
(3) De-braze two fittings (5) then remove bushings (6) and pressure regulator valve (7) (para 5.10).
Figure 5-14. Pressure Regulator Valve (Discharge)
5-38