TM9-4120-370-14
TO35E9-229-1
(9) Spin fan and check that there is no interference with inlet bell.
(10) Usingscrewdriver and wench, secure motor cable with a clamp, screw, and nut.
(11) If the other fan was remove, go back to step (1) and install the other fan
(12) Connect motor cable connectors.
be connected with the power on, Exercise extreme
The following test must
caution.
(13) Connect power and turn mode selector switch on VENTILATE. Check that fans are rotating in proper
(14) Turn unit OFF
1, Install conditioned air filter. (See para 432.)
Followon procedures:
4-60. EVAPORATOR FAN
MOTORS (B3 AND
B4)
Preliminary procedures:
a. Test (Installed)
(1) Check to see that power has been disconnected.
(2) Check motor for rotational freedom by spinning fan. If there is any stiffness or binding, contact direct sup-.
port maintenance.
(3) Check motor bearings for lateral or end play. If there is excessive lateral or end play, contact direct support
maintenance.
(4) Electrically test motor as follows: