TM9-4120-370-14
TO35E9-229-1
(1) Check to see that power has been disconnected
(2) Disconnect motor cable connector.
CAUTION
Take care that capillary tubing wires and cables are not damaged.
(3) Support or hold motor in place and note number and location of shims as mounting hardware is removed.
(4) Using two wrenches, remove four cap screws, flat washers, and nuts from motor mount.
(5) Lift motor and shims from unit.
Installation (Requires two people.)
c.
CAUT ION
Take care that capillary tubing wires and cables are not damaged.
(1) Lift motor into position, insert shims in same location as motor that was removed. (See b, (3) above.)
(2) Using two wrenches, secure motor to mount with four screws, flat washers, and nuts
(3) See paragraph 4-63 and install fans. Do not install lower front panel or condenser fan covers
(4) Spin fans and check for interference, Adjust fans in or out on shaft Adjust motor front to rear by loosening
mounting screws, or up and down by adding or removing shims as needed.
(5) Connect P2 harness connector to motor.
Follow-on procedures:
4-65. SAFETY CONTROL BOX ASSEMBLY
Preliminary procedure:
CAUTION
Disconnect input power to the air conditioner before performing any internal
maintenance. Voltages used can KILL. Shutting the unit off at the control panel
does not disconnect unit power.
Access
a.
(1) Turn power off at power source.
(2) Disconnect power cable at air conditioner.
NOTE
On models F36T2SA and F36T4-2SB remove condenser air deflector door. (See para