ARMY TM 9-4120-380-14
NAVY EE-000-BA-MMA-010/7053-AC
AIR FORCE TO 35E9-136-21
Section II. DIRECT SUPPORT MAINTENANCE PROCEDURES-Continued
Liquid Quench Service Valve (V3) ....................................................................................... 5-54
Receiver Service Valve (V2) ................................................................................................ 5-56
Damper Actuator Service Valve (V1) ................................................................................... 5-58
Solenoid Valves (L1 and L2) ................................................................................................ 5-61
Expansion Valve(V5) (Primary) ............................................................................................ 5-64
Expansion Valve (V6) (Liquid Quench) .. ............................................................................ 5-69
Hot Gas Bypass Valve (V4) ................................................................................................. 5-74
Damper Actuator ................................................................................................................ 5-78
Damper Actuator Connecting Link ...................................................................................... 5-81
Distributor ........................................................................................................................... 5-84
Service Valves (V9 and V8) (Discharge and Suction) . ....................................................... 5-86
Compressor (B2) . ............................................................................................................... 5-88
Vibration Eliminators (VE1 and VE2) ................................................................................... 5-95
Receiver ............................................................................................................................. 5-97
Refrigerant Strainer (F2) ...................................................................................................... 5-99
Tubing end Fittings ............................................................................................................ 5-101
5.4 GENERAL. This section contains maintenance procedures which are authorized to Direct Support Maintenance
(F) by the Maintenance Allocation Chart (MAC) Appendix and Source. Maintenance and Recoverability (SMR) coded
Items Each paragraph covers a complete maintenance procedure but may require other tasks to be included (I.e., initial
setups, references and follow-on procedures). Perform procedures/tasks in designated order.
5.5 PANELS AND INFORMATION PLATES. For removal, inspection, cleaning, and installation refer to the following
paragraphs.
d. Condenser Duct Refer to General Support Maintenance.
f. Repair (Chassis). Repairs are limited to straightening of minor dents, rewelding of broken welds, installation
of loose or missing rivets and rivnuts, replacement of captive fasteners, replacement of loose or missing bushings,
grommets, gaskets and installation paint touch up, and replacement of damaged or missing information plates.
(1) Minor Dents Repair minor dents using standard sheet metal repair practices.
(2) Broken Welds. Repair broken welds using standard weld repair practices.
5-2