TM 9-4120-385-14
31.
Loosen four captive screws retaining junction box.
Disconnect P10 and P4 connectors.
32.
33.
34.
Disconnect ground lead.
Disconnect leads to run capacitor (C1).
35.
36.
Remove junction box from casing.
b.
INSPECTION.
1.
Check wires and leads for fraying and proper connection.
2.
Check circuit breaker handle and arm for damage.
3.
Check condition of guard.
4.
Check all electrical components inside junction box for external damage.
5.
Check relay mounting bracket for damage.
6.
Check for damaged insulation.
7.
Inspect terminal boards for cracks, damaged or loose terminals, and corrosion.
WARNING
Dry cleaning solvent used to clean parts is potentially dangerous to
personnel and property.
Do not use near open flame or excessive heat. Flash point of
solvent is 100 F to 138 F (38 C to 59 C).
8.
Remove corrosion with abrasive cloth. Clean terminal boards with solvent. Dry
with a clean cloth.
9.
Inspect wiring harness for broken leads, missing terminals, and broken solder
joints.
10. Inspect junction box for cracks, bends, and breaks. Replace as necessary.