TM 9-4120-385-14
11. Continuity Checks.
(a) To test terminal board: Using 10 megohms megger, check continuity between each terminal pin and
board. Continuity should not be indicated. Check continuity between three pins of neighboring terminal pins. Continuity
should not be indicated. If continuity is indicated, terminal board must be replaced.
(b) Refer to Table 4-5 and perform continuity checks on wiring harness. Continuity should be indicated.
Table 45. JUNCTION BOX WIRING HARNESS CONTINUITY CHECK
FROM
TO
J4-A
TB22
J4a
J4B
J4-X
J4-C
TB1-4
J4-D
TB21
J4-E
TB2-3
J4-F
TB22
J4-G
J4-H
K1X2
J4-I
TB17
J4-J
TB2-5
J4-K
J4f
J4-L
CB-C
TB2-4
J4M
J4N
TB1-1
TB11
J4-P
TB1-4
J4-R
J4-T
E2
TB15
J4-W
J4-Y
K2-X2
J4Z
TB2-4
XF22
J4-b
J4-c
E2
J4--d
TB25
TB2-6
J4-e
J4-g
TB1-8
TB25
J4-j
J4-k
TB17
TB12
J4-S
J4-U
TB1-1
K1A1
J4-b
J4V
J10-C
J10-M
TB1-4
TB21
J10-L
J10-E
TB13