TM 9-4120-388-14
5-28. CONDENSER COIL.
This task covers:
a. Removal
b. Repair
c. Installation
INITIAL SETUP:
Equipment Condition
Receiver removed (5-26).
Condenser coil guard removed (4-26).
Side access cover removed (4-22).
a.
Removal.
(1) Observe position of tubing from condenser for ease of reassembly.
(2) While purging the system with nitrogen, debraze the remaining tube joints to the condenser. (See para 5-8
and 5-9.)
When handling coils, wear gloves to avoid cuts and reduce fin damage on the coil.
(3) Remove four pan head screws from each side while supporting the condenser coil.
(4) Remove the eight flat head screws from the front flanges of the coil.
(5) Using gloves to protect your hands and coil fins, carefully slip the coil and brackets from unit.
5-67