5. Remove two screws (5), tube and plunger assembly (4), O-ring (6), and diaphragm (7) from new valve
body (8).
6. Install flush bushings (11) in valve body (8).
8. Secure valve body (8) to housing with two screws (9) and spacers (10).
9. Install O-ring (6), diaphragm (7), and tube and plunger assembly (4). Secure to valve body (8) with two
screws (5).
10. Install coil (3) and data plate (2), with attaching nut (1) on tube and plunger assembly (4).
NOTE
FOLLOW-ON MAINTENANCE: