TM9-4120-400-14
PRESSURE RELIEF VALVE. - continued
5-31.
4. Hold fitting (10)and install valve(11).
5. Secure valve (11) with clamp (9), screw(6), lock washer(7), and flat washer(8).
6. Install clamp (5) and chain (4) with screw (1), lock washer(2), and flat washer(3).
NOTE
FOLLOW-ON MAINTENANCE:
Replacement
This task covers:
INITIAL SETUP
Equipment Condition
TOOIS
Refrigeration Unit Service Tool Kit
Gloves
General
Safety
Instructions
Materials/Parts
Condenser Coil
Lock Washers (3)
When handling coils wear gloves to avoid cuts and
reduce fin damage.
REPLACEMENT
1. Remove two screws (1) and lock washers (2) and mounting plate (3).
2. Remove four screws (4) and two clamps (5) from the receiver(6).
3. Remove screw (7), nut (8), lock washer (9), and clamp (10) from coil (11).
4. Debraze tube connection (12) on the coil (11). (See para 5-12.)
When handling coils wear gloves to avoid cuts and reduce fin damage.
5. Carefully lift condenser coil (11), sight glass (13), and receiver (6) up and out of unit.
5-71