TM 9-4120-401-14
4-4.
SERVICE UPON RECEIPT OF MATERIAL. - continued
The unit weight (less shipping pallet) is 282 pounds (127.9 kg). When lifting or
moving the unit on the shipping pallet, a forklift may be used. To avoid
injury when lifting the unit into position, use four people, one at each lifting
handle.
(4) Tilt the unit and pallet or raise the unit using a forklift. Remove the four bolts from the bottom of the
pallet. Using four people (one at each lifting handle), carefully lift the unit from the shipping pallet.
INSTALLATION
INSTRUCTIONS.
a. Air Conditioner Preparation For Installation.
(1) Two input power connectors are provided on the air conditioner. Connector J4 is located on the front
of the air conditioner beside the control panel assembly. Connector J5 is located on the rear of the air conditioner
in the upper left corner. Determine which connector best suits your installation. If power source is inside
conditioned area, use J4. If power source is outside conditioned area, use J5.
(a) Air conditioners are shipped from the factory wired for the use of the J4 power connector. If this
connector is used no change is necessary.
Figure 4-2. Cable Connection Changes for J4/J5 (Front/Rear) Power Input Connectors