TM 9-4120-402-14
4-34. CONTROL ASSEMBLY. - continued
a. Remove.
(1) Disconnect power cable from control assembly if attached.
(2) Remove screw (1) and flat washer (2).
(3) Remove 12 sets of screws (3), lock washers (4), andflat washers (5).
(4) Carefully pull control assembly (6) from unit as far as wiring harnesses will allow.
(5) Tag and disconnect wiring harness connectors (7) from unit.
b. Inspect.
Check control assembly (6) for dents, punctures, or any other damage.
c.
Repair.
d. Replace.
Replace enclosure (6) if damaged and any damaged components.
e. Install.
(1) Connect wiring harness connectors (7) to unit using tags and wiring diaram figure 4-10. Remove tags.
g
(2) Carefully install control assembly (6) into unit.
(3) Secure control assembly (6) with 12 sets of screws (3), lock washers (4), and flat washers (5).
(4) Install screw (1) and flat washer (2).
(5) Connect power cable to control assembly if disconnected.
NOTE
FOLLOW-ON MAINTENANCE:
Connect power at power source.
4-106