TM 9-4120-407-14
3-29. CAPACITORS (C3, C4, C5, C6, AND C7) TESTING AND REPLACEMENT. (Cont)
(c) Remove two screws (7).
(d) Remove screw (8), lock washer (9), flat washer (10), and two capacitors (6). Discard lock
washer.
(2) Capacitors C5, C6, and C7 Removal.
(a) Remove two screws (1) Figure 3-44, lock washers (2), flat washers (3), cover (4), and two posts
(5). Discard lock washers.
Figure 3-44. Capacitors (C5, C6, and C7)
(b) Tag wire leads connected with capacitors (6) leads.
(c) Remove three screws (7).
(d) Remove screw (8), lock washer (9), flat washer (10), and three capacitors (6). Discard lock
washer.
terminal leads of individual capacitors. A capacitance of between 0.00376 and 0.00564 F should be
indicated. Replace any defective capacitors.
3-110