A. WIRE MAY BE OPEN FROM MAIN POWER SOURCE TO FORWARD SIDE OF STARTER.
1 Connect one multimeter lead to contact L1 (1) at main
power source and connect other lead to contact L1 (2)
at forward side of starter.
2 Remove both leads. Connect one multimeter lead to
contact L2 (3) at main power source and connect other
lead to contact L2 (4) at forward side of starter.
3 Remove both leads. Connect one multimeter lead to
contact L3 (5) at main power source and connect other
lead to contact L3 (6) at forward side of starter.