TM 9-4910-387-14-2
6-2.
TROUBLESHOOTING (cont)
I.
WIRES MAY BE OPEN. (cont)
NOTE
Reset relay is part of the stepping relay.
5 Remove both leads. Connect one multimeter lead to holding relay
coil contact (22). Connect other lead in sequence to terminal D9
(23), reset relay coil contact (24), and to latching relay contact (25).
6 Remove both leads. Connect one multimeter lead to terminal D10
(26). Connect other lead in sequence to latching relay contact (27)
and reset relay coil contact (28).
NOTE
7 Remove both leads. Connect one multimeter lead to terminal D8
(29). Connect other lead in sequence to latching relay contact (30)
and to terminal C7 (31).
6-106