TM 9 4910-387-14-2
A. LOW CAM SPEED STOP MAY BE SET INCORRECTLY.
NOTE
1 Turn main power source on and set speed at
lowest point by pushing START button and then
Configurations
and
SLOW button.
troubleshooting checks of
the remote control motor may
2 Push STOP button and turn main power source
vary from tester to tester. For
off.
older tester models, refer to
3 Remove cover (1) on remote control motor.
4 Loosen screw (2) and move low cam speed stop (3) further away from low
speed microswitch (4). Tighten screw (2).
5 If drive speed of tester will not decrease, proceed to step B.
6-133