TM 9-4910-387-14-2
6-5. RH CONTROL EQUIPMENT ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont)
REASSEMBLY OF RH MOUNTING BOARD ASSEMBLY (cont)
NOTE
Wires were tagged with termination points at
disassembly. Ensure that wires are connected to
correct locations.
Use solder (item 18, app C ) for all the following
12 WIRE. Solder bare end to
selenium rectifier contact (21) and
position other end with terminal lug on terminal C5.
13 WIRE WITH TERMINAL LUG TAGGED XI FROM CONTROL
14 SCREW (22). Install through two terminal lugs into terminal C5.
15 WIRE WITH TERMINAL LUG TAGGED H1 FROM CONTROL
16 SCREW (23). Install through terminal lug into terminal C6.
6-202