functioning in accordance with the manufac-
counterclockwise, and all on-off toggle
t u r e r ' s specifications for ampere and voltage
switches to "OFF" position (some
o u t p u t when operating under normal condi-
t o g g l e switches have center position
tions.
(2) M o u n t t h e
b. Tabulated Data.
(pulley- or
direct-driven) undergoing
(1) Pulley-driven.
test on low
speed driving head (5, fig.
Manufacturer
The Leece-Neville
7 ) pars. 94
or 95) as shown in fig-
Company
50.
Federal stock number
2920-314-0556
Manufacturer's model
Type A0015320GP and
5320-G12P
as applicable for the type (pul-
or
O r d n a n c e number
8376691
l e y - or direct-driven) generator (al-
Rated voltage
28 volts
t e r n a t o r ) undergoing test.
Rated amperes
100 amperes
S p e e d range
1,650 to 8,000 rpm
N u m b e r brushes
4 (2 pair)
( p u l l e y - or direct-driven) to the al-
Rotation
nondirectional
ternator input binding posts (12, fig.
Weight
37 pounds
F i e l d current
8 to 10 amperes at 100
applicable leads and cable harness sets
a m p e r e s output
(2) Direct-driven.
(5) C o n n e c t a connecting link (fig. 65)
Manufacturer
The Leece Neville
between "B+" and "G+" and between
Company
"B-" and "G-" regulator binding
Manufacturer's model
Type A0015504AA
O r d n a n c e number
10922191
48.
Rated voltage
28 volts
R a t e d amperes
100 amperes
(6) Remove the rectifier mounting bracket
Speed range
1,650 to 8,000 rpm
a s s e m b l y from the rectifier compart-
N u m b e r brushes
4 (2 pair)
ment and mount a rectifier,
Rotation
nondirectional
above, (ordnance number 7954343) of
Weight
37 pounds
k n o w serviceable condition (see note
F i e l d current
8 to 10 amperes at 100
c above) on
the bracket assembly (fig.
a m p e r e output
49).
(3) Rectifier. (Used with pulley or direct-
(7) P l a c e t h e r e c t i f i e r a n d m o u n t i n g
driven generator) (alternator) (figs.
bracket assembly (6) above, in the
49 and 52)
rectifier compartment as shown in fig-
Manufacturer
The Leece Neville
Company
Manufacturer's model
Type C0011029CP
(8) Lower or raise the rectifier and mount-
O r d n a n c e number
7954343
ing bracket assembly, so the rectifier
Rated volts
28 volts
is centered in the air flow of the air
Rated amperes
100 amperes
vents in the rectifier compartment, and
c. Preparation.
with the fins of the rectifier vertical
with the flow of air.
for
performance check the rectifier, (3) above, for service-
(9) C o n n e c t the rectifier
to the binding
ability as prescribed in TM 9-7003 or TB 9-2300-
posts in the rectifier
compartment, as
206-15.
using applicable
( 1 ) Turn all switches beneath the meters
c a b l e harnesses (fig.
o n the test stand to the maximum
r e a d i n g position, all rheostats fully
rectifier compartment
door.