TM 9-4935-481-14-1
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D (10275000) Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
COUNTER
COUNTER
INHIBIT(SEC)
CT
TEST
INHIBIT(SEC)
CT
TEST
Dial
RESET
START
Reading
Dial
RESET
START
Reading
63
0002
Actuate
Actuate
19.9 to 20.1 msec
85
0500
Actuate
Actuate
4999.5 to 5000.5 msec
64
0003
Actuate
Actuate
29.9 to 30.1 msec
86
0600
Actuate
Actuate
5999.4 to 6000.6 msec
65
0004
Actuate
Actuate
39.9 to 40.1 msec
87
0700
Actuate
Actuate
6999.3 to 7000.7 msec
66
0005
Actuate
Actuate
49.9 to 50.1 msec
88
0800
Actuate
Actuate
7999.2 to 8000.8 msec
67
0006
Actuate
Actuate
59.9 to 60.1 msec
89
0900
Actuate
Actuate
8999.1 to 9000.9 msec
FREQ/TIME/MULT switch to 13.
68
0007
Actuate
Actuate
69.9 to 70.1 msec
90
CT
0
69
0008
Actuate
Actuate
79.9 to 80.1 msec
91
1000
Actuate
Actuate
9999 to 10001 msec
70
0009
Actuate
Actuate
89.9 to 90.1 msec
92
2000
Actuate
Actuate
19998 to 20002 msec
71
0010
Actuate
Actuate
99.9 to 100.1 msec
Corrective action for steps 63 through
72
0020
Actuate
Actuate
199.9 to 200.1 msec
92 is ; (13)
73
0030
Actuate
Actuate
299.9
to
300.1
msec
93
MCP
SELECTOR A switch to G8.
74
0040
Actuate
Actuate
399.9
to
400.1
msec
94
MCP
SELECTOR B switch to A13.
75
0050
Actuate
Actuate
499.9
to
500.1
msec
95
MCP
SELECTOR C switch to G14.
76
0060
Actuate
Actuate
599.9
to
600.1
msec
96
CIP
RUN/HOLD/OFF switch to OFF.
77
0070
Actuate
Actuate
699.9 to 700.1 msec
CAUTION
*Repositioning SELECTOR A and B switches while the 1W20 cable is
78
0080
Actuate
Actuate
799.9 to 800.1 msec
connected between J12 and J13 will result in damage to DMS circuit
79
0090
Actuate
Actuate
899.9 to 900.1 msec
components
.
2
80
CT
FREQ/TIME/MULT switch to 10
.
97
MCP
Connect a 1W20 cable between J12 and J13.
81
0100
Actuate
Actuate
999.8 to 1000.2 msec
98
DMM
Observe a HI reading.
82
0200
Actuate
Actuate
1999.8 to 2000.2 msec
(14)
83
0300
Actuate
Actuate
2999.7 to 3000.3 msec
99
PPE
FUNCTION TEST switch to TTS COUNTER INHIB ONLY.
84
0400
Actuate
Actuate
3999.6 to 4000.4 msec
100
CIP
COUNTER INHIBIT(SEC) dial to 01.00.
101
CIP
RUN/HOLD/OFF switch to RUN.
102
PPE
Momentarily actuate TEST START switch.
3-80