TM 9-4935-481-14-1
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
591
VWS
Set PERIOD(MS) dial to the positions indicated and observe the Counter reading for each setting. If
PPE
counter reading is lost momentarily actuate TEST START switch.
PERIOD (MS)
Reading
PERIOD (MS)
Reading
609
010.0
9,95 to 10.05 msec
610
020.0
19.95 to 20.05 msec
592
358.1
358.05 to 358.15 MS
611
030.0
29.95 to 30.05 msec
Replace card A11. Check A11 pins 120, 108, 116, 117, 118
612
040.0
39.95
to
40.05
msec
and 119.
613
050.0
49.95
to
50.05
msec
593
003.0
2.95 to 3.05 msec
614
060.0
59.95
to
60.05
msec
594
003.1
3.05 to 3.15 msec
615
070.0
69.95
to
70.05
msec
595
003.2
3.15 to 3.25 msec
616
080.0
79.95 to 80.05 msec
596
003.3
3.25 to 3.35 msec
617
090.0
89.95 to 90.05 msec
597
003.4
3.35 to 3.45 msec
618
100.0
99.95 to 100.05 msec
598
003.5
3.45 to 3.55 msec
619
200.0
199.95 to 200.05 msec
599
003.6
3.55
to
3.65
msec
620
300.0
299.95 to 300.05 msec
600
003.7
3.65
to
3.75
msec
621
400.0
399.95 to 400.05 msec
601
003.8
3.75
to
3.85
msec
622
500.0
499.95 to 500.05 msec
602
003.9
3.85
to
3.95
msec
623
600.0
599.95 to 600.05 msec
603
004.0
3.95 to 4.05 msec
624
700.0
699.95 to 700.05 msec
604
005.0
4.95 to 5.05 msec
625
800.0
799.95 to 800.05 msec
605
006.0
5.95 to 6.05 msec
626
900.0
899.95 to 900.05 msec
606
007.0
6.95 to 7.05 msec
627
999.9
999.85 to 999.95 msec
607
008.0
7.95 to 8.05 msec
Corrective action for steps 593 through 627 is: Replace card A10.
608
009.0
8.95 to 9.05 msec
3-98