TM9-4935-481-14-1
C3
Table 3-11. DMS-D Performance Test-Continued
Table 3-11. DMS-D Performance Test-Continued
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
Replace card A5. Check A5 pins
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
40, 103, and 111.
696
PPE
SEQUENCE switch to AUTO 7.
707
1
17.01
+5.181 to +5.233 Vdc
697
ITP
INTERNAL TEST switch to 1.
(96)
698
DMM
Observe a reading of +0.8780 to +0.8860 Vdc.
Replace card A4. Check A4 pins
708
18.39
+5.181 to +5.233 Vdc
95, 2, 91 and 110.
(96)
699
CIP
COUNTER INHIBIT(SEC) dial to 00.34.
700
CIP
RUN/HOLD/OFF switch to RUN.
709
1
18.41
+5.853 to +5.91 Vdc
1
701
PPE
SEQUENCE switch to AUTO 8.
(95)
702
PPE
Momentarily actuate TEST START switch.
Record reading.
703
ITP
Set INTERNAL TEST switch to the positions indicated. Then set
CIP
RUN/HOLD/OFF switch to HOID, the COUNTER INHIBIT(SEC) dial to
710
2
Record reading.
DMM
the positions indicated, the RUN/HOLD/OFF switch to RUN, wait
711
3
Record reading.
for INHIBIT lamp to illuminate, then observe the DMM reading
for each series of switch settings. Record the DMM reading in
712
Compute the difference between step 709 and 710. The difference shall be 0.6123 to 0.6317 Vdc.
steps 709, 710 and 711 for use in steps 712 and 713.
(97)
INTERNAL TEST
COUNTER INHIBIT(SEC)
Reading
713
Compute the difference between step 709 and 711. The difference shall be 0.6123 to 0.6317 Vdc.
704
1
00.35
-0.0050 to +0.0050 Vdc
Replace card A5. Check A5 pins
(92)
40, 103, and 111.
714
PPE
SEQUENCE switch o AUTO 9.
705
00.36
+5.853 to +5.911 Vdc
715
CIP
COUNTER INHIBIT(SEC) dial to 00.63.
(95)
716
PPE
Momentarily actuate TEST START switch.
717
ITP
Set INTERNAL TEST switch to the positions indicated. Then set
706
16.99
+5.853 to +5.911 Vdc
CIP
(95)
DMM
RUN/HOLD/OFF switch to HOLD, the COUNTER INHIIBIT(SEC) dial to
3-102