TM9-4935-481-14-1
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
STEP
UNIT
PROCEDURE
CORRECTIVE ACTION
NOTE
2
MCP
Connect 1W11-P1 to J9.
The major units and panels will be identified by the initials as indicated below.
3
Connect the alligator clips to the batteries, observing polarity.
DMS-D
CAUTION
DMM
Insure DMS switch is in OFF position. No testing
is to be performed using the DMS while batteries
PP
POWER panel
are being charged.
MCP
MONITOR/CONTROL panel
CAUTION
TTS
TRACKER TEST SET
Insure any unused alligator clips are not electrically touching
each other or a metal surface.
NOTE
4
PP
MAIN POWER switch to ON.
The DMS-D provides an average charging current of 365 ma. Approximately 16
hours is required to raise a completely discharged battery to a fully charged
Allow batteries to charge for 16 hours. Steps 6 through
state. The batteries may be charged at this rate indefinitely without damage to
9 may be performed during the charging operation to verify
batteries or DMS-D. Four batteries may be connected and charges
batteries are being charged.)
simultaneously using cable assembly 1W11.
6
MCP
DMM switch to DMM INPUT>
1
7
MCP
DMM LO switch to EXT
NOTE
8
Monitor with the DMM probes (observing polarity at each battery.
For fault isolation marked by a ( ), see pages at the end of this table.
9
DMM
Observe batteries are charging and reach a terminal velocity of +11.2 Vdc at the end of 16 hours.
(1)
10
PP
MAIN POWER switch to OFF.
11
MCP
Disconnect 1W11 from J9 and the battery (or batteries).
12
PP
MAIN POWER switch to ON>
3-203