TM 55-1925-286-13&P
0012 00
Table 1. Operator Preventive Maintenance Checks and Services Including Lubrication (continued)
ITEM
INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
13
Weekly
1.0
Compressed Air
Check the compressed air piping
Any leaks in the
Piping
system for leaks.
piping system.
14
Weekly
0.2
Automatic Drain
Check for leaks, loose connections,
damage, and proper operation.
AUTOMATIC DRAIN
15
Semi-
8.0
Air Compressor
annually
maintenance supervisor to have
(1000
direct support maintenance
operating
remove the compressor valves
hours)
and check for indications of
leakage and/or carbon buildup.
maintenance supervisor to have
direct support maintenance remove
and clean the sump strainer
screen.
Table 2. Compressor Oil
Ambient Temperature
ISO Viscosity
NSN
32-80 F (0-27 C)
Non-Detergent, Non-Synthetic 68
60-104 F (16 to 40 C)
Non-Detergent, Non-Synthetic 100
END OF WORK PACKAGE
0012 00-6