TM 9-2330-211-14&P
LUBRICATION CHART
SEMITRAILER, LOWBED: 25 TON, 4 WHEEL, M172A1
Intervals (on-condition or hard time) and related
use near open flame or excessive heat. The
solvent's flash point is 100F - 138F
man-hour times are based on normal operation. The
(38C - 59C). If you become dizzy while using
man-hour time specified is the time you need to do all
cleaning solvent, immediately get fresh air and
services prescribed for a particular interval. De-
medical help. If solvent contacts eyes,
crease the intervals if your Iubricants are contami-
immediately wash your eyes and get medical
nated, or if you are operating equipment under
aid.
adverse conditions, including longer-than-usual op-
Clean all fittings and area around lubrication points
erating hours. The intervals may be extended during
periods of low activity. If extended, adequate preser-
equivalent before lubricating equipment. After lubri-
vation precautions must be taken.
cation, wipe off excess oil or grease to prevent accu-
Dotted leader lines indicate lubrication is required on
mulation of foreign matter.
both sides of the equipment.
The lowest level of maintenance authorized to lubri-
cate a point is indicated in parentheses by use of the
WARNING
following: (C) Operator/Crew; or (O) Unit Mainte-
nance.
Dry cleaning solvent P-D-680 is toxic and
flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated
NOTE
area. Avoid contact with skin, eyes, and
LV is Localized View.
clothes, and DO NOT breathe vapors. DO NOT