GENERAL. This section describes, illustrates,
and furnishes the operator with information pertaining to
the controls required for operation of the converter
assembly.
2-2.
CONTROLS.
a.
Pressure Cap (1). The pressure cap attaches
to the fuel press adaptor (2) to seal off the
A safety chain is attached to the pressure cap
and fuel press adaptor.
The pressure cap
should be installed on the fuel press adaptor
whenever the converter assembly is not being
used to fuel a tank.
b.
Levers (3). There are two levers which are
used to engage the latches to lock the converter
assembly in the tank during the fueling
operation. The levers rotate the latches to the
engaged position and then when engaged lock
the latches against the under side of the
manhole flange to apply pressure to the sealing
gasket.