TM 9-4120-404-14
14. Place S6 in the "OFF" position. Reset previous fault condition by turning the mode switch, S7, to
"OFF/RESET" position, and then back to "H" position. Place S4 in the "ON" position for 2
seconds, and then turn S4 off. The following routine shall occur:
a.
LED 1 shall turn off LED 7 shall remain illuminated.
b.
For the next 8 seconds:
LED 4 illuminates.
LED 7 remains illuminated.
c.
For the next 2 seconds:
LED's 4 and 7 turn off.
d.
For the next 2 seconds:
LED 4 shall continue to be off.
LED's 1 and 7 shall illuminate. End of routine.
15. Place S5 in the "ON" position for 2 seconds, then place S5 in the "OFF" position. The following
routine shall occur:
a.
LED 1 shall turn off LED 7 shall remain illuminated.
b.
For the next 8 seconds:
LED 5 illuminates.
LED 7 remains illuminated.
c.
For the next 2 seconds:
LED's 5 and 7 turn off.
d.
For the next 2 seconds:
LED 5 shall continue to be off.
LED's 1 and 7 shall illuminate. End of routine.
16. Place S6 in the "ON" position for 2 seconds, then place S6 in the "OFF" position. The following
routine shall occur:
a.
LED 1 shall turn off LED 7 shall remain illuminated.
b.
For the next 8 seconds:
LED 6 illuminates.
LED 7 remains illuminated.
c.
For the next 2 seconds:
LED's 6 and 7 turn off.
3-93