TM 9-4120-405-13&P
Table 3-1. Operator Troubleshooting. (cont.)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Check for proper connection of intervehicular cable plug at towing vehicle's receptacle.
Pull intervehicular cable plug out and reinsert cable plug into receptacle.
14. ONE OR MORE LAMPS FAIL TO LIGHT.
Check for loose connection between terminal assembly and electrical contact at bad light.
Push terminal assembly into electrical contact until they lock; if malfunction still exists, notify your
supervisor.
15. DIM OR FLICKERING LAMPS.
Check for loose connection between terminal assembly and electrical contact at bad light.
Push terminal assembly into electrical contact until it locks.
16. BRAKES OVERHEAT.
Check for unreleased handbrake lever.
Release handbrake lever. If malfunction still exists, notify your supervisor.
17. ABNORMAL OR UNEVEN TIRE WEAR.
Check tire pressure.
Inflate both tires to 35 psig (241 kPa). If malfunction still exists, notify your supervisor.
Section III. OPERATOR MAINTENANCE PROCEDURES
3-4. GENERAL. This section contains the maintenance procedures authorized for operator maintenance as defined in
the Maintenance Allocation Chart located in Appendix B. Before performing any procedures in this section, use the
Operator troubleshooting procedures to identify and locate the parts on the trailer-mounted, generator-set powered, air
conditioner requiring maintenance. Refer to TM 5-6115-585-12 for operator maintenance on the generator-set.
3-10