TM 5-1940-322-10
0037 00
OPERATION UNDER UNUSUAL CONDITIONS (Contd)
SLAVE STARTING BEB
NOTE
When jumping from an external 24V power source, a
standard NATO slave receptacle is provided adjacent to
the master power switch in the battery compartment. Use
a standard NATO slave cable to slave to this receptacle.
1.
Acquire NATO slave cable (1) from CBT stowage compartment.
2.
Remove NATO slave receptacle dust cap (3) from NATO slave receptacle (2) on
CBT.
3.
Connect NATO slave cable (1) to NATO slave receptacle (2) on CBT.
4.
5.
Remove NATO slave receptacle dust cap (5) from NATO slave receptacle (4) on
BEB.
6.
Connect NATO slave cable (1) to NATO slave receptacle (4).
7.
8.
Disconnect NATO slave cable (1) from NATO slave receptacle (4) and (2), and
install dust caps (5) and (3) on receptacles (4) and (2).
9.
10.
Stow NATO slave cable (1) in CBT stowage compartment.
1
~
4
6
5
3
2
END OF WORK PACKAGE
0037 00-6