TM 5-1940-322-10
0046 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) (Contd)
Table 1. Preventive Maintenance Checks and Services (Contd).
ITEM
ITEM TO
NOT FULLY
INTERVAL
PROCEDURE
NO.
CHECK/SERVICE
MISSION CAPABLE IF:
26. Before
c. Instrument panel switches and
gauges as follows:
(Contd)
NOTE
Procedure steps in (1) and (2) are
to be performed on both engines.
(1)
Move STARBOARD/PORT
Check port and
(1) Engine will not
starboard engine
ENGINE CIRCUIT
start.
circuits
switches to ON position;
alarm will sound and red
low oil indicator will
illuminate. Move alarm
mute switch to up position
and release. Alarm will
stop for 90 seconds, then
alarm will come back on.
CAUTION
Do not leave transmission
engaged for more than 30 seconds
when boat is out of water. Failure
to comply may cause damage to
equipment.
NOTE
Open hydrojet inspection hatches
prior to performing step 2.
(2)
Move and hold
(2) Engine will not
STARBOARD/PORT
start.
START switch to up
position and start
starboard and port engine.
Engage starboard/port
transmission into forward.
Move starboard scoop
control lever to reverse
position and scoop will
lower. Look through diving
platform flaps to verify
scoop movement. Check all
starboard and port engine
gauges for proper
operation. Check starboard
and port gauges and shut
down engine.
0046 00-15