TM 5-2420-230-10
Table 3-1. Operator/Crew Preventive Maintenance Checks and Services (PMCS) for IHMEE. (Continued)
Item to be
Checked or
Not Fully Mission
Item
Serviced
Procedure
Capable If:
No.
Interval
Not properly charged or
After
Fire Extinguisher
a. Check for proper charge level.
22
missing.
b. Check mounting bracket for loose or
missing hardware.
Either seat belt or seat
After
Operator's Seat, Seat
a. Check operator's seat belt and seat
23
anchor torn or belt
Belt, and Seat Anchor
anchor for damage.
retractor inoperative.
Seat latch inoperative or
b. Check operator's seat adjustment latch.
broken.
Seat adjuster inoperative
c. Check operator's seat suspension
or broken.
adjuster.
Operator's seat hardware
d. Check operator's seat for damaged
loose or missing.
upholstery, loose or missing hardware,
and ease of operation.
Instrument panel lights do
After
Instrument Panel
Move lights switch through all positions and
24
not illuminate (if mission
Lights
check that instrument panel lights are
is to occur during low
light or night time).
After
Instrument Panels and
Inspect the instrument panels for broken
Any of the following
25
Controls
glass and unserviceable gauges.
gauges are unreadable:
ENGINE COOLANT
TEMPERATURE
ENGINE OIL
PRESSURE
TRANSMISSION OIL
TEMPERATURE
TRANSMISSION OIL
PRESSURE
Reverse alarm
After
Reverse Alarm
With ignition switch in IGN position, shift
26
inoperative.
EGS to R (Reverse). Check reverse alarm
operation (if tactical situation permits).
After
Hourmeter
Check hourmeter for physical damage.
Hourmeter damaged.
27
3-12
Change 1