TM 55-1925-282-14&P
0012 00
ITEM INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
11
Quarterly
2.0
Reverse Osmosis Clean RO membrane elements when
(RO) Membranes production of product water decreases
by 10% or when salinity meter readings
indicate product water produced
contains more than 300 ppm salt
! CAUTION
12
Semi-
0.2
High Pressure
annually
Pump Electric
Use only polyurea base grease in the
Motors
high pressure pump motors. The use
of lithium or silicone base grease will
damage the high pressure pumps.
Apply three pumps of polyurea base
grease to each grease fitting on the
high pressure pump motors.
GREASE FITTINGS
13
500 Hours
1.0
High Pressure
Change high pressure pump oil every
Pump
END OF WORK PACKAGE
0012 00-4