TM 55-1925-282-14&P
0018 00
1
4
3
2
Figure 2. ROWPU System Pressure Regulator Valve
! CAUTION
Media tank inlet pressure must not exceed 45 PSI (3.1 bar) and differential pressure
must not exceed 35 PSI (2.4 bar), or damage could occur to the media filter tank.
4. Turn the adjustment screw (figure 2, item 4) clockwise to increase system pressure or counterclockwise to
decrease system pressure as indicated on the media filter INLET PRESSURE gauge RO-PG-2 (figure 3,
item 1).
5. Adjust media tank inlet pressure to a maximum of 45 PSI (3.1 bar).
0018 00-3