TM 55-4920-394-13&P
e.
Carefully inspect the electrical wiring for broken wires or frayed insulation. Check that all electrical
connections are secure.
f.
Inspect the oil reservoir for evidence of physical damage during shipment. Check that the gage
sensors are securely mounted in the oil reservoir. Check that the electrical wiring to the sending
unit is not damaged.
g.
Check tires for proper inflated pressure. Normal tire pressure should be 60 pounds with tires cold.
Inspect tire treads and casings for cuts or abrasons and remove any imbedded objects from
i
treads.
h.
Check the towbar and steering assemblies. Make certain that tie rods have not been bent or
damaged and that the steering apparatus swings freely.
i.
Check hand brake assembly by setting the hand brake and testing rear wheels for braking action.
j.
Inspect the test stand trailer and cabinet for any damage, making certain that all bolts and screws
are secured. Check doors and door latches for proper closing and locking.
3-4. Servicing Hydraulic System. To service the hydraulic system for use, proceed as outlined in the
following steps.
a.
Position the test stand convenient to 220/440 V, 3 phase, 60 HZ power outlet.
b.
If the hydraulic fluid reservoir (2, fig. 1-4) has been filled with a preservative fluid for shipment,
drain the reservoir by removing the reservoir drain cap in the bottom of the reservoir. Make certain
drain cap is installed after reservoir has been completely drained.
c.
Drain the preservative fluid (if necessary) from the hydraulic system at each filter drain for the low
pressure filters. When completely drained, replace drain caps.
d.
drain plug located in the corner of the pump case. When completely drained, replace plug. Refill
pump case with MIL-H-5606 or MIL-H-82382.
e.
Connect power cord plug to 220/440 V, 3 phase, 60 HZ outlet. Place power on switch located on
the electrical control panel in ON position. This will energize the reservoir level gage located on
the
control panel.
f.
Fill the test stand reservoir at the filler neck with hydraulic fluid, Specification MIL-H-5606 or MIL-H-
82382 until the reservoir level gage indicates 3/4 to 7/8 full.
3-5. Preliminary Lubrication .
Carefully inspect the test stand lubricating points referred to in
Table 3-3. Be
sure that initial
3-2