TM 9-2320-209-10-1
Set Hi-LO switch (1) to LO position.
1.
Hold START-OFF-RUN switch (2) in START position until indicator light (3) comes
2.
on. Indicator light should come on within two minutes.
NOTE
START-OFF-RUN switch (2) is spring loaded and must be
held in position.
As soon as indicator light (3) comes on, quickly move START-OFF-RUN switch (2)
3.
to RUN position.
NOTE
Moving switch (2) lever from START to RUN too slowly will
result in a heater shutdown. Warm air should be felt at the
heat outlet within three minutes.
If heater fails to start within two-minutes, (indicator light (3) remains off), move
4.
STAR T-OFF-RUN switch (2) to OFF position. Wait until three minutes before
trying again to start.
Set HI-LO switch (1) to HI or LO depending on heat needed.
5.
NOTE
LO position of HI-LO switch (1) is suitable for standby
periods when heater will operate for a long period of time.
GO TO FRAME 4