TM 9-2320-269-10
TROUBLESHOOTING TABLE - CONTINUED
HYDRAULIC FLUID
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Loss of fluid.
CAUTION
Should fluid level become so low as to uncover the inlet pipe opening in the reservoir, extensive damage to
hydraulic pump may result.
Check reservoir pressure and return lines/hoses for loose connections or leaks.
If loose connections or leaks are found, notify organizational maintenance.
TA 222693
3-32