TM 9-2330-246-14
4-105. TERMINAL ENTRANCE ASSEMBLY REPLACEMENT (M348A2F) (Con't).
Use adhesive to install new top and bottom gaskets (12) and two new side gaskets (13) on cover (10) using
5.
adhesive.
Install new coated cloth (2) on hinge (3).
6.
7.
Install hinge (3) on cover (10) using four new rivets (5). From inside of cover, peen rivets so that they are flush.
Install hinge (3) and cover (1 O) on frame (1) using five new rivets (4). From interior side of frame, peen rivets so
8.
that they are flush.
Apply metal seam sealing tape around opening where frame installs. Install frame (1) on semitrailer using nine
9.
screws (15).
FOLLOW-ON TASKS:
Install incoming power cables.
TA700333
4-252