TM 9-2330-247-14&P
PRESSURE TANK AND RELAY VALVE (Con't)
4-43.
ACTION
ITEM
REMARKS
LOCATION
NOTE
Ensure that pressure tank is positioned with draincock at
bottom.
Two U-bolts (12)
Put in place.
13.
Bracket (1)
and pressure
tank (11 )
Four lock-
Two U-bolts (12),
Screw in and tighten using
in. socket, exten-
14.
washers (2)
in. drive.
bracket (1),
and nuts (3)
and pressure
tank (11)
Nut (7)
a. Wrap threads of elbow (8) clockwise two turns
Air hose (6)
15.
with antiseizing tape.
and elbow (8)
in. open-end box
b. Screw in and tighten using
wrench.
Two nuts (4)
a. Wrap threads of straight adapters (5) clockwise
16.
two turns with antiseizing tape.
and two straight
adapters (5)
in. open-end box
b. Screw in and tighten using
wrench.
FOLLOW-ON MAINTENANCE:
TASK ENDS HERE
TA701104
4-98