TM 9-2330-357-14&P
4-43. FAIL-SAFE AIRBRAKE CHAMBER REPLACEMENT (Con't).
b. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear
protective goggles and gloves, and use only in a well-ventilated area.
Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors.
DO NOT use near open flame or excessive heat. The solvent's flash
point is 100 -138 (38 -59 ). If you become dizzy while using
F
F
C
C
cleaning solvent, immediately get fresh air and medical help. If solvent
contacts eyes, immediately wash your eyes and get medical aid.
1. Remove all buildup of dirt or grease by using a clean rag and dry cleaning solvent, and allow to dry.
2. Check threaded end of fail-safe airbrake chamber for burrs or other damage.
c. INSTALLATION
1. Place fail-safe airbrake chamber (2) into position and tighten nut (3) on clamp ring (4).
2. Uncap and connect two air lines (1) to fail-safe airbrake chamber (2) as tagged.
FOLLOW-ON TASKS:
Pressurize airbrake system (para 2-10) and check for leaks.
4-87