TM 9-2330-381-14
4-77.
FOUR-WAY DIRECTIONAL CONTROL VALVE BANK (CONT)
NOTE
The stud assembly has a nut and lockwasher on each end. Use a tool at each end
to hold one nut and loosen the other during removal of stud assembly.
1.
Remove three nuts (1), lockwashers (2), and stud assemblies (3) from valve bank (4). Discard all lockwashers
from stud assemblies (3).
2.
Using a suitable prying device, carefully pry valve inlet (5) from linear directional control valve (6). Remove
preformed packings (7, 8, 9, and 10) from valve inlet (5). Discard preformed packings.
3.
Using a suitable prying device, carefully pry linear directional control valve (6) from linear directional control valve
(11). Remove preformed packings (12, 13, 14, and 15) and shim (16) from linear directional control valve (6).
Discard preformed packings and shim.
4-372 Change 1