Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
LEFT FRONT MARKER
3.
Check for continuity across
1.
Set digital multimeter to
LIGHT DOES NOT
circuit breaker CB7.
ohms.
ILLUMINATE - CONTINUED
2.
Connect positive (+) probe
of digital multimeter to one
terminal on circuit breaker
CB7.
3.
Connect negative (-) probe
of digital multimeter to
other terminal on circuit
breaker CB7.
4.
Note reading on digital
multimeter.
5.
If continuity is not present,
replace circuit breaker CB7
0036 00-26


 