7.
RIGHT STOPLIGHT DOES
5.
Connect negative (-) probe
NOT ILLUMINATE -
of digital multimeter to
CONTINUED
terminal lug TL252 and not
reading on digital
6.
If continuity is not present,
repair wire between
connector J259 and terminal
lug TL252 (WP 0043 00) or
replace electrical cable
assembly (WP 0051 00). If
continuity is present replace
voltage converter box (WP
7.
Close voltage converter box
cover (WP 0053 00).
8.
connect connector J259 to
right stoplight connector.