Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. LEFT BLACKOUT TAILLIGHT
1.
Check to see if 18-26 vdc is
1.
Disconnect 24 vdc
DOES NOT ILLUMINATE
present at 24 vdc
intervehicular cable from
intervehicular cable
connector pin A.
2.
Set digital multimeter to
ohms.
3.
Connect positive (+) probe
of digital multimeter to 24
vdc intervehicular cable
connector pin A.
4.
Connect negative (-) probe
of digital multimeter to a
known good ground.
5.
Position towing vehicle main
light switch to SER DRIVE
and note reading on digital
multimeter.
6.
Position towing vehicle main
light switch to OFF.
7.
If 18-26 vdc is not present,
replace 24 vdc intervehicular
cable (WP 0164 00, Item 2).
0036 00-77


 


Privacy Statement - Copyright Information. - Contact Us