TM 9-2330-394-13&P
CIRCUIT BREAKER AND MODULE REPLACEMENT - Continued
0053 00
MODULE REMOVAL
NOTE
This task shows locations of Voltage Converter Box module wiring connection points. Refer
to Table 1. Voltage Converter Box Module Wiring Connections for details.
Modules 1 through 5 are remove the same way, Module 3 shown.
Tag wires and connection points prior to disconnecting.
Remove plastic cable ties as required.
Table 1. Voltage Converter Box Module Wiring Connections.
MODULE
CONNECTION POINTS
1
CB3, left ground stud, Pin #2-12 volt connector, E-Pin-24 volt connector
2
CB4, left ground stud, Pins #4/#5-12 volt connector, J-Pin-24 volt connector
3
CB7, right ground stud, Pin #6-12 volt connector
4
CB8, right ground stud, Pins #3/#4-12 volt connector, B-Pin-24 volt connector
5
CB1, right ground stud, Pins #4/#7-12 volt connector, B-/J-/K-Pins-24 volt connector
1.
Remove wire (21) from pin #6 of 12 volt connector (22).
0053 00-10