PUSH-PULL/AIR SUPPLY VALVE REPLACEMENT - Continued
0062 00
REMOVAL - Continued
NOTE
Note orientation of fittings prior to removal.
4.
Remove three 90-degree fittings (2) from push-pull/air supply valve (4).
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off
harmful vapors, and are harmful to skin and clothing. Keep away from open
fire and use in a well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
Failure to comply may result in injury to personnel.
0062 00-3


 