Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
MECHANICAL STOP AND RESILIENT MOUNT REPLACEMENT
0076 00
- Continued
RESILIENT MOUNT REMOVAL, MTVT
1.
Position mechanical stop (3) in vise.
2.
Remove nut (5), lockwasher (6), bolt (7), and resilient mount (8) from mechanical stop (3). Discard
lockwasher.
RESILIENT MOUNT INSTALLATION, MTVT
1.
Position resilient mount (8) on mechanical stop (3) with bolt (7), lockwasher (6), and nut (5).
Tighten nut (5) to 35-46 lb-ft (47-63 Nm).
2.
3.
Remove mechanical stop (3) from vise.